Loading...
12-15-2025 (Zoning Board of Adjustment) Agenda Packet P a g e | 1 Wylie Zoning Board of Adjustments Regular Meeting December 15, 2025 – 6:00 PM Council Chambers - 300 Country Club Road, Building #100, Wylie, Texas 75098 CALL TO ORDER COMMENTS ON NON-AGENDA ITEMS Any member of the public may address Board regarding an item that is not listed on the Agenda. Members of the public must fill out a form prior to the meeting in order to speak. Board requests that comments be limited to three minutes for an indiv idual, six minutes for a group. In addition, Board is not allowed to converse, deliberate or take action on any matter presented during citizen participation. CONSENT AGENDA All matters listed under the Consent Agenda are considered to be routine by the Board and will be enacted by one motion. There will not be separate discussion of these items. If discussion is desired, that item will be removed from the Consent Ag enda and will be considered separately. A. Consider and act upon approval of the meeting minutes from the November 17, 2025 Zoning Board of Adjustments meeting. REGULAR AGENDA 1. Hold a Public Hearing to consider and act upon a request by Wylie Ladera LLC for a variance to Section 22- 450.C(9) of the Sign Ordinance to allow for a Monument Sign of the allowed maximum square footage and structure height. Property located near 1590 Bella Way. (ZBA 2025-16). WORK SESSION RECONVENE INTO REGULAR SESSION EXECUTIVE SESSION RECONVENE INTO OPEN SESSION Take any action as a result from Executive Session. ADJOURNMENT CERTIFICATION I certify that this Notice of Meeting was posted on December 09, 2025 at 5:00 p.m. on the outside bulletin board at Wylie City Hall, 300 Country Club Road, Building 100, Wylie, Texas, a place convenient and readily accessible to the public at all times. 1 P a g e | 2 ___________________________ ___________________________ Stephanie Storm, City Secretary Date Notice Removed The Wylie Municipal Complex is wheelchair accessible. Sign interpretation or other special assistance for disabled attendees must be requested 48 hours in advance by contacting the City Secretary’s Office at 972.516.6020. Hearing impaired devices are available from the City Secretary prior to each meeting. If during the course of the meeting covered by this notice, the Board should determine tha t a closed or executive meeting or session of the Board or a consultation with the attorney for the City should be held or is required, then such closed or executive meeting or session or consultation with attorney as authorized by the Texas Open Meetings Act, Texas Government Code § 551.001 et. seq., will be held by the Board at the date, hour and place given in this notice as the Board may conveniently meet in such closed or executive meeting or session or consult with the attorney for the City concerning any and all subjects and for any and all purposes permitted by the Act, including, but not limited to, the following sanctions and purposes: Texas Government Code Section: § 551.071 – Private consultation with an attorney for the City. 2 Zoning Board of Adjustment AGENDA REPORT Department: Planning Item: A Prepared By: Gabby Fernandez Subject Consider, and act upon, minutes from the November 17, 2025 Regular Meeting. Recommendation Motion to approve Item A as presented. Discussion The minutes are attached for your consideration. 3 12/15/2025 Item A. Wylie Zoning Board of Adjustments Regular Meeting November 17, 2025 – 6:00 PM Council Chambers - 300 Country Club Road, Building #100, Wylie, Texas 75098 CALL TO ORDER Chair Covington called the meeting to order at 6:00 p.m. In attendance were Chair Richard Covington, Board Member Senedu Asfaw, Board Member Gordon Hikel, Board Member Freddy A Nana Yodou. Staff present were Director of Community Services Jasen Haskins, Senior Planner Kevin Molina, and Administrative Assistant Gabby Fernandez. Vice-Chair Nathan Cole arrived at 6:03 PM. COMMENTS ON NON-AGENDA ITEMS Any member of the public may address Board regarding an item that is not listed on the Agenda. Members of the public must fill out a form prior to the meeting in order to speak. Board requests that comments be limited to three minutes for an individual, six minutes for a group. In addition, Board is not allowed to converse, deliberate or take action on any matter presented during citizen participation. None approached the Board. CONSENT AGENDA All matters listed under the Consent Agenda are considered to be routine by the Board and will be enacted by one motion. There will not be separate discussion of these items. If discussion is desired, that item will be removed from the Consent Agenda and will be considered separately. A. Consider and act upon approval of the meeting minutes from the October 20, 2025 Zoning Board of Adjustments meeting. BOARD ACTION A motion was made by Board Member Hikel and seconded by Board Member A Nana Yodou to approve the Consent Agenda as presented. A vote was taken and carried 4 – 0. REGULAR AGENDA 1. Hold a Public Hearing to consider and act upon a request by Aleyda Murillo for a variance to Section 2.5.C.4 & 2.5.C.5 of Zoning Ordinance to allow for an accessory structure within 1’ side and rear setbacks in lieu of the required 3’. Property located at 3001 Admiral Drive. (ZBA 2025-15). Chair Covington opened the public hearing at 6:13 PM. A member of the public approached the Board to provide comment. Chair Covington closed the public hearing at 6:17 PM. BOARD ACTION A motion was made by Board Member Hikel and seconded by Chair Covington to approve Regular Agenda Item 1 as presented. A vote was taken and carried 5 – 0. Page | 1 4 12/15/2025 Item A. ADJOURNMENT A motion was made by Board Member Hikel, and seconded by Vice-Chair Cole, to adjourn the meeting. A vote was taken and carried 5 – 0. Chair Covington adjourned the meeting at 6:26 PM. ______________________________ Richard Covington, Chair ATTEST ______________________________ Gabby Fernandez, Secretary Page | 2 5 12/15/2025 Item A. Wylie Zoning Board of Adjustments AGENDA REPORT Department: Planning Item Number: 1 Prepared By: Kevin Molina Subject Hold a Public Hearing to consider and act upon a request by Wylie Ladera LLC for a variance to Section 22 -450.C(9) of the Sign Ordinance to allow for a Monument Sign of the allowed maximum square footage and structure height. Property located near 1590 Bella Way. (ZBA 2025-16). Recommendation Motion to approve or deny. Discussion OWNER: Wylie Ladera LLC APPLICANT: Johnson Volk Consulting The applicant is requesting a variance to Section 22-450.C(9) of the Sign Ordinance to allow for an entry residential subdivision monument sign that is over the maximum allowed square footage of 96 square feet and over the maximum allowed height of 8’. The request is to allow for a monument sign which contains a stone accent wall that measures approximately 98 square feet with a maximum height of 6’8” which is attached to a stone entry tower that measures approximately 105 square feet with a maximum height of 14’ 2”. The sign is proposed to be installed on a median leading to the gates of the Ladera residential community. The purpose of the Sign Ordinance restricting residential monument signs is to regulate the visual impact, and neighborhood character of a subdivision. The applicant believes the variance request has merit for the following reasons: - The monument sign is being proposed for a privately maintained gated community which will remain under one sole property owner that is managed by a Condominium Owners Association. The street where the sign is proposed is to be privately maintained. - The sign is being proposed at the main entrance leading to a gated community and is not directly adjacent to any neighboring homes. - The monument sign is not negatively affecting the viability of the intersection between Bella Way and Country Club road. - The monument sign is proposed not only for signage but as a distinctive architectural element for the age -restricted Ladera residential community. The developer has an existing similar concept in the Ladera Proposer Community. Public comment forms were mailed to eight (8) property owners within 200 feet of this request, as required by State Law. At the time of posting, no comment forms were returned in favor or in opposition of the request. The Board shall not grant a variance to the development code which: (1) Permits a land use not allowed in the zoning district in which the property is located; or (2) Is in the public right-of-way or on public property; or (3) Alters any definition of the development code; or 6 12/15/2025 Item 1. (4) Is other than the minimum variance that will afford relief with the least modification possible to the requirements of the development code; or (5) Is based on physical conditions or circumstances of the property so general or recurring in nature as to reasonably make practicable the formulation of a general regulation to be adopted as an amendment to the development code; or (6) Is based exclusively on findings of personal or financial hardship. In order to grant a variance to the development code the Board shall find that all the following have been satisfied: (1) That there are unique physical circumstances or conditions of the lot, or other exceptional physical condition particular to the affected property; (2) That because of these unique physical circumstances or conditions, the property cannot be reasonably developed or used in compliance with the provisions of the development code; (3) That due to such unique physical circumstances or conditions, the strict application of the development code would create a demonstrated hardship; (4) That the demonstrable hardship is not self-imposed; (5) That the variance if granted will not adversely affect the proposed development or use of adjacent property or neighborhood; (6) That the variance, if granted will not change the character of the zoning district in which the property is located; (7) That the variance, if granted is in keeping with the intent of the development code; and (8) That the variance, if granted, will not adversely affect the health, safety or welfare of the citizens of Wylie. 7 12/15/2025 Item 1. 8 12/15/2025 Item 1. 912/15/2025 Item 1. OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHULADERAA LADERA LIVING 55+ COMMUNITYHS7 of 100l:\cjs-s drive\projects\gam\gam038\dwg\gam038-hs.dwg JVC No GAM038SCALE:One Inch1" = 20'LADERA WYLIE PHASE 1 CITY OF WYLIE COLLIN COUNTY, TEXAS SCREENING AND BUFFERING .HIOO D JSTE C CCTTES AET STAIREG 3OF28ETX NRLDRE CAANDSLEPAHSONY 3October 22, 2025HARDSCAPE DETAILSREFER TODETAILSSCALE: 1/2"=1'-0"PRIMARY ENTRY MONUEMENTELEVATION2MATERIAL SELECTIONDRY STACK LUEDERS STONE VENEERMEDIUM BRONZE3BIG BLOCK LUEDERS STONE VENNERSCALE: 1" = 10'-0"PRIMARY ENTRY MONUEMENTPLAN1!! WARNING!!APPROXIMATE LOCATION OF EXISTINGABOVE GROUND UTILITIES. CONTRACTORSHALL COORDINATE WITH APPROPRIATEUTILITY COMPANIES PRIOR TOCONSTRUCTION.COUNTRY CLUB ROAD 14'-2" HT. STONEENTRY COLUMN.6'-6" HT. ENTRYSIGN PANEL.7'-0" HT. STONECOLUMN.6'-0" HT. ORNAMENTALMETAL FENCE.7'-0" HT. VEHICULARSWING GATE.(ENTRANCE)7'-0" HT. ORNAMENTALMETAL FENCE.7'-0" HT. VEHICULARSWING GATE.(EXIT)6'-0" HT. ORNAMENTALMETAL FENCE.7'-0" HT. STONECOLUMN.BARRIER FREE RAMP PER CITYSTANDARDS. REFER TO CIVILPLANS FOR DETAILS, TYP.6'-0" WIDTH CONCRETE SIDEWALKPER CITY STANDARDS. REFER TOCIVIL PLANS FOR DETAILS, TYP.6'-0" HT. BRICKTHINWALL PANEL.6'-6" HT. BRICKTHINWALL COLUMNSPACED 12'-0" O.C. MAX.10 U.E.10 U.E.15 B.L.UTILITYPOLE, TYP.20' UTILITYEASEMENT.FHWMWATERWATER BRISA WAYSIGHT VISIBILITYEASEMENTLARGE CANOPYTREE, TYP.HS81HS81SHRUBS & GROUNDCOVER, TYP.SHRUBS & GROUNDCOVER, TYP.15'-11"STONE ACCENT WALLS.1'-4" HT. PIN-MOUNTEDSTEEL LETTERING.5" HT. PIN-MOUNTEDSTEEL LETTERING.14'-2" HT. STONE ENTRY TOWER.REFER TO DETAILS 1&2/HS7A.8'-0"18'-2"26'-2"VARIABLE HT. SIGN WALLREFER TO DETAIL 1/HS7B.HS7B1HS7B4HS7A1&26'-8" 14'-2"8'-0"8'-0"8'-0"10'-3"2'-3"8'-0"1012/15/2025 Item 1. HS7A of 100l:\cjs-s drive\projects\gam\gam038\dwg\gam038-hs.dwg JVC No GAM038SCALE:One Inch1" = 20'LADERA WYLIE PHASE 1 CITY OF WYLIE COLLIN COUNTY, TEXAS SCREENING AND BUFFERINGOctober 22, 2025HARDSCAPE DETAILSREFER TODETAILSSECTIONSCALE: 3/4" = 1'-0"PRIMARY ENTRY COLUMN114'-2"5'-0"4'-1"3"1'-8"9'-6"4'-3"VOID6'-9"2'-4"5'-8"2'-9"1'-6"6"2'-0"FINAL GRADE3" CLR ALL SIDES8-#5 BARS TOP AND BOTTOM8-#3 STIRRUPSCONCRETE FOOTING(8'-0" x 26'-2" x 18")CONTINUOUS 6" HT. VOID BOX BYSAVWAY BENEATH PIER CAP WITH 12"HT. SOIL RETAINER BOARD ALL SIDES.2-2" CONTINUOUS FLAGSTONE WATERTABLEWITH 1" OVERHANG EACH COURSE.4" ASHLAR PATTERN DRY STACK LUEDERSTONE VENEER. CONNECT TO CMU WALLWITH GALVANIZED WALL TIESTRIANGULARLY SPACED AT 1 PER 4 SQ FT.32 - #5 VERTICAL REBARS SPACED 16" O.C.EXTEND TO TOP OF WALL.8" HT. CMU BOND BEAM WITH 2-#4 REBAR TOP ANDBOTTOM CONTINUOUS. FILL WITH COARSEGROUT. ON TOP OF BOND BEAM PROVIDE DOUBLE2X6 SILL TREATED WITH 12" J-BOLT INTO GROUTEDCELL AT 32" O.C.2X8 FRAMING @ 16" O.C.2"x12" FASCIA BOARD WITH 1"x4" TOPBOARD. PAINT PER OWNER SELECTION.2X6 STUD @ 12" O.C.2X4 RAFTER @ 16" O.C.STANDING SEAM METAL ROOF W/ 3/4" CDXTOP LAYER AND #30 FELT. COLOR AND SPECSHALL BE SELECTED BY OWNER.(3) 2X6 HEADER5"BIG BLOCK LUEDER STONE VENEER.CONNECT TO CMU WALL WITHGALVANIZED WALL TIES TRIANGULARLYSPACED AT 1 PER 4 SQ FT.14'-2" 5'-0"4'-1"3"1'-8"9'-6"4'-3"VOID6'-9"2'-4"5'-8"2'-9" 1'-6"6"2'-0"3" CLR ALL SIDES27-#5 BARS TOP AND BOTTOM27-#3 STIRRUPSCONCRETE FOOTING(8'-0" x 26'-2" x 18")CONTINUOUS 6" HT. VOID BOX BYSAVWAY BENEATH PIER CAP WITH 12"HT. SOIL RETAINER BOARD ALL SIDES.8 - 24" DIA. CONCRETE PIER.REFER TO DETAIL 3/HS7B.FOR PIER SPACING REFER TODETAIL 2/HS7.2-2" CONTINUOUS FLAGSTONE WATERTABLEWITH 1" OVERHANG EACH COURSE.4" ASHLAR PATTERN DRY STACK LUEDERSTONE VENEER. CONNECT TO CMU WALLWITH GALVANIZED WALL TIESTRIANGULARLY SPACED AT 1 PER 4 SQ FT.32 - #5 VERTICAL REBARS SPACED 16" O.C.EXTEND TO TOP OF WALL.8" HT. CMU BOND BEAM WITH 2-#4 REBAR TOP ANDBOTTOM CONTINUOUS. FILL WITH COARSEGROUT. ON TOP OF BOND BEAM PROVIDE DOUBLE2X6 SILL TREATED WITH 12" J-BOLT INTO GROUTEDCELL AT 32" O.C.2X8 FRAMING @ 16" O.C.2"x12" FASCIA BOARD WITH 1"x4" TOPBOARD. PAINT PER OWNER SELECTION.2X6 STUD @ 12" O.C.2X4 RAFTER @ 16" O.C.STANDING SEAM METAL ROOF W/ 3/4" CDXTOP LAYER AND #30 FELT. COLOR AND SPECSHALL BE SELECTED BY OWNER.(3) 2X6 HEADER5"BIG BLOCK LUEDER STONE VENEER.CONNECT TO CMU WALL WITHGALVANIZED WALL TIES TRIANGULARLYSPACED AT 1 PER 4 SQ FT.6 - #5 VERTICAL REBARS SPACED 16" O.C.EXTEND TO TOP OF WALL.HS7B4HS7A2MORTAR FILL AS NEEDED.2'-0"6'-3"8 - 24" DIA. CONCRETE PIER.REFER TO DETAIL 3/HS7B.FOR PIER SPACING REFER TODETAIL 2/HS7.2'-0"4'-0"MORTAR FILL AS NEEDED.8"X8"X16" CMU BLOCK WITHSTONE FACADE. FILL ALL CMUCELLS CONTAINING VERTICALREBAR WITH COARSE GROUT.SECTIONSCALE: 3/4" = 1'-0"PRIMARY ENTRY COLUMN2October 22, 2025F-108268"X8"X16" CMU BLOCK WITHSTONE FACADE. FILL ALL CMUCELLS CONTAINING VERTICALREBAR WITH COARSE GROUT.4"X8"X16" CMU BLOCK WITH STONE FACADE.FILL ALL CMU CELLS CONTAINING VERTICALREBAR WITH COARSE GROUT.1112/15/2025 Item 1. LADERAA LADERA LIVING 55+ COMMUNITYHS7B of 100l:\cjs-s drive\projects\gam\gam038\dwg\gam038-hs.dwg JVC No GAM038SCALE:One Inch1" = 20'LADERA WYLIE PHASE 1 CITY OF WYLIE COLLIN COUNTY, TEXAS SCREENING AND BUFFERINGOctober 22, 2025HARDSCAPE DETAILSREFER TODETAILS3"1'-1"3"1'-1"3"5"5"3"3"7"1'-4"6"2'-8"1'-4"1'-4"1'-4"6'-8"6'-5"4'-8"3'-0"1'-3"1'-6"6"8 - 24" DIA. CONCRETE PIER.REFER TO DETAIL 3/HS7B.FOR PIER SPACING REFER TO DETAIL2/HS7.3" CLR ALL SIDES8-#5 BARS TOP AND BOTTOM CONTINUOUS8-#3 STIRRUPSCONCRETE FOOTING(8'-0" x 26'-2" x 18")FINISH GRADECONTINUOUS 6" HT. TRAPEZOIDALVOID BOX BY SAVWAY BENEATHGRADE BEAM.#5 VERTICAL REBAR SPACED 16" O.C.EXTEND TO TOP OF WALL.4" STONE VENEER, ASHLAR PATTERN ON FRONT SIDE OFWALL. CONNECT TO CMU BLOCK WITH GALVANIZED WALLTIES TRIANGULARLY SPACED AT 1 PER 4 SQ FT.3" LUEDERS SLABS TO ACT AS CONTINUOUSWALL CAP. PROVIDE 2" OVERHANG EACHCOURSE. CONNECT TO CMU BLOCK WITHGALVANIZED WALL TIES TRIANGULARLYSPACED AT 1 PER 4 SQ FT.5" HT. HIDDEN PIN MOUNTED LETTERING.LETTERING TO BE ARIAL FONT WITH 1.00TRACKING.1'-4" HT. HIDDEN PIN MOUNTED LETTERING.LETTERING TO BE GABRIOLA FONT WITH 1.20TRACKING.SCALE: 3/4"=1'-0"VARIABLE HT. ENTRY SIGN WALLSECTION112' MIN. DEPTH IN CLAY ORWEATHERED ROCK, OR 2' MIN. PENETRATION INTOUNWEATHERED ROCK WITH 6' MIN. DEPTH, OR8'-0" DEPTH INTO NATIVE SOIL WHERE PIERS ARE CONSTRUCTED IN FILL.30"SECTIONSCALE: 3/4" = 1'-0"PIER (24" DIA.)SECTIONPLAN1'-6"2'-0"3"PLANEQUALDOUBLE TIE AT TOP6-#5 BARS VERTICAL#3 ROUND STIRRUP@ 18" O.C.PIER CAP ORFOOTING PER PLAN4-#5 HOOKS, 8"x36"6-#5 VERTICAL BARS @EQUAL SPACING AROUNDSPIRAL#3 ROUND STIRRUP @18"ON CENTER31'-4"7'-11"5"SCALE: 3/4"=1'-0"ENTRY SIGN LETTERINGSECTION25" HT. HIDDEN PIN MOUNTED LETTERING.LETTERING TO BE ARIAL FONT WITH 1.00TRACKING.1'-4" HT. HIDDEN PIN MOUNTED LETTERING.LETTERING TO BE GABRIOLA FONT WITH 1.20TRACKING.10'-2"SCALE: 3/4"=1'-0"VARIABLE HT. ENTRY SIGN WALLSECTION44" STONE VENEER, ASHLAR PATTERN ONFRONT SIDE OF WALL. CONNECT TO CMUBLOCK WITH GALVANIZED WALL TIESTRIANGULARLY SPACED AT 1 PER 4 SQ FT.#5 VERTICAL REBAR SPACED 16" O.C.EXTEND TO TOP OF WALL.8"X8"X16" CMU BLOCK WALL WITHSTONE FACADE. FILL ALL CMUCELLS WITH COARSE GROUT.3" CLR ALL SIDES8-#5 BARS TOP AND BOTTOM CONTINUOUS.8-#3 STIRRUPSCONCRETE FOOTING(8'-0" x 26'-2" x 18")CONTINUOUS 6" HT. TRAPEZOIDALVOID BOX BY SAVWAY BENEATHGRADE BEAM.TOWER MONUMENT BEYOND.October 22, 2025F-108263'-0"1'-10"5'-10"1'-10" 7'-8" 1'-6"6"8 - 24" DIA. CONCRETE PIER.REFER TO DETAIL 3/HS7B.FOR PIER SPACING REFER TO DETAIL2/HS7.2'-0"4'-0"2'-0"8"X8"X16" CMU BLOCK WITH STONE FACADE. FILLALL CMU CELLS CONTAINING VERTICAL REBAR WITHCOARSE GROUT.4"X8"X16" CMU BLOCK WITH STONE FACADE.FILL ALL CMU CELLS CONTAINING VERTICALREBAR WITH COARSE GROUT.1212/15/2025 Item 1. Disclaimer: Before providing us with your approval for printing, please take time to carefully review all text and graphics for any errors. (i.e. spelling, grammar, phone numbers, addresses, colors, layout, size, etc.) *ALL SIGNAGE QUOTES ARE VALID FOR 15 DAYS* Sign SpecificationsSign SpecificationsSign Specifications Extra Notes:Extra Notes:Extra Notes: Office: Austin 607 Leander Dr, Ste 100 | Leander, TX 512.259.9100 | www.dr-signs.net Office: Austin 607 Leander Dr, Ste 100 | Leander, TX 512.259.9100 | www.dr-signs.net Office: Austin 607 Leander Dr, Ste 100 | Leander, TX 512.259.9100 | www.dr-signs.net©2024 72" Revision: v2 Letter Size: ASSORTED/see measurements Single or Double Sided: Single Sided Letter Size: ASSORTED/see measurements Single or Double Sided: Single Sided Letter Size: ASSORTED/see measurements Single or Double Sided: Single Sided Materials: Face Substrate: 1/4” painted aluminum Materials: Face Substrate: 1/4” painted aluminum Materials: Face Substrate: 1/4” painted aluminum Work Order: QUOTE Date: 9/22/2025 Client: Ladera Accnt Manager: Lindsey S. Designer: Jess C. Scale: 1/12 Routed aluminum letters painted to match PMS, stud-mounted to stone. PAGE 1/1QTY.X1 44" 161" 13" 13" 12" 191" 181" 170" 6" 33" 37" 83" 6" 160" 13 12/15/2025 Item 1. 2603 1605 1901 1903 1902 7906 1903 1613 7903 7960 1507 1601 1811 1909 2201 1705 1905 1713 6939 1705 1901 7907 1809 1618 7905 1902 7904 19021634 1511 1609 1707 1901 7905 1617 1902 1619 1710 1908 1911 1900 1638 1902 1715 1636 1706 2605 1601 190416121602 1640 1900 1615 1520 1901 1902 7940 1901 1803 19061907 1524 1801 1611 1603 1809 1606 1904 1813 1508 18131901 1623 1903 1905 1907 1711 2601 1900 1509 20001609 1703 1906 1900 1603 1712 1707 7900 1903 1701 1614 1903 1503 1608 1704 1905 1900 1702 1620 1615 8430 2301 1906 15131903 1610 1904 1906 1600 1607 1900 1605 1642 1604 1902 1709 1906 1611 18151905 1904 1701 1505 1903 7904 1908 1900 1600 1514 1613 1902 2600 1907 1902 1708 1711 1607 1907 1903 1904 1908 19041905 1807 1805 1904 1709 1700 1622 1909 1901 1907 1905 1616 1900 1904 2455 2605 2457 2221 8516 2625 2505 200 foot Notification Buffer SUBJECT property Wylie City Limit ¯ ZONING BOARD OF ADJUSTMENT CASE: ZBA 2025-16 Ladera Date: 11/20/2025 ¯ Notification Map 01002003004005006007008009001,000FeetCountry Club RdCITY LIMIT CITY LIMI TCITY LIMITCITY LIMIT14 12/15/2025 Item 1.