Loading...
Ordinance 2020-301 1 ORDINANCE NO. 2020-30 AN ORDINANCE OF THE CITY OF WYLIE, TEXAS, AMENDING THE COMPREHENSIVE ZONING ORDINANCE OF THE CITY OF WYLIE, AS HERETOFORE AMENDED, SO AS TO CHANGE THE ZONING ON THE HEREINAFTER DESCRIBED PROPERTY, ZONING CASE NUMBER 2020-02, FROM AGRICULTURAL (AG) TO PLANNED DEVELOPMENT (PD), TO ALLOW FOR A MIXED USE AGE RESTRICTED MASTER PLANNED COMMUNITY; PROVIDING FOR A PENALTY FOR THE VIOLATION OF THIS ORDINANCE; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE; AND PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the Planning and Zoning Commission and the governing body of the City of Wylie, Texas, in compliance with the laws of the State of Texas with reference to the amendment of the Comprehensive Zoning Ordinance, have given the requisite notices by publication and otherwise, and after holding due hearings and affording a full and fair hearing to all property owners generally and to owners of the affected property, the governing body of the City is of the opinion and finds that the Comprehensive Zoning Ordinance and Map should be amended; NOW, THEREFORE BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF WYLIE, TEXAS: SECTION 1: That the Comprehensive Zoning Ordinance of the City of Wylie, Texas, be, and the same is hereby, amended by amending the Zoning Map of the City of Wylie, to give the hereinafter described property a new zoning classification of Planned Development (PD), said property being described in Exhibit A (Legal Description), hereto and made a part hereof for all purposes. SECTION 2: That Planned Development Conditions and a Zoning Exhibit are an integral component of the development of the property and are attached as Exhibits B and C, respectively. SECTION 3: That all ordinances of the City in conflict with the provisions of this ordinance be, and the same are hereby, repealed and all other ordinances of the City not in conflict with the provisions of this ordinance shall remain in full force and effect. SECTION 4: That the above described property shall be used only in the manner and for the purposes provided for in the Comprehensive Zoning Ordinance of the City, as amended herein by the granting of this zoning classification. SECTION 5: Any person, firm or corporation violating any of the provisions of this ordinance or the Comprehensive Zoning Ordinance, as amended hereby, commits an unlawful act and shall be subject to the general penalty provisions of Section 1.5 of the Zoning Ordinance, as the same now exists or is hereafter amended. Ordinance No. 2020-30 - change the zoning on the hereinafter described property, zoning case number 2020-02, from agricultural (ag) to planned development (pd) SECTION 6: Should any paragraph, sentence, subdivision, clause, phrase or section of this ordinance be adjudged or held to be unconstitutional, illegal or invalid, the same shall not affect the validity of this ordinance as a whole or any part or provision thereof, other than the part so declared to be invalid, illegal or unconstitutional, and shall not affect the validity of the Comprehensive Zoning Ordinance as a whole. SECTION 7: This ordinance shall be in full force and effect from and after its adoption by the City Council and publication of its caption as the law and the City Charter provide in such cases. SECTION 8: The repeal of any ordinance, or parts thereof, by the enactment of this Ordinance, shall not be construed as abandoning any action now pending under or by virtue of such ordinance; nor shall it have the effect of discontinuing, abating, modifying or altering any penalty accruing or to accrue, nor as effecting any rights of the municipality under any section or provisions of any ordinances at the time of passage of this ordinance. DULY PASSED AND APPROVED by the City Council of the City of Wylie, Texas, this 26th day of May 2020. ATTEST: Stephanie Storm, City Secretary DATE OF PUBLICATION: June 3, 2020, in the Eiacl�ogue, Ma r. Ordinance No. 2020-30 - change the zoning on the hereinafter described property, zoning case number 2020-02, from agricultural (ag) to planned development (pd) 1 EXHIBIT A 1 1 1 Being a tract of land situated in the William Patterson Survey, Abstract No. 716, Collin County, Texas, same being that tract of land conveyed to Katheryn Skinner, a single woman, by deed recorded in County Clerk File No. 20070514000648930, Real Property Records of Collin County, Texas, and being more particularly described by metes and bounds as follows: BEGINNING at a point for corner, said corner being the Northeast corner of Wylie United Methodist Church, an Addition to Collin County, Texas, according to the Map or Plat thereof recorded in Volume R, Page 213, Map or Plat Records of Collin County, Texas and Tying along the West line of FM Road 1378 (50-foot right-of-way); THENCE South 89 degrees 30 minutes 53 seconds West, along the North line of said Wylie United Methodist Church Addition, a distance of 620.19 feet to a 5/8 inch iron rod found for corner, said corner being the Northwest corner of said Wylie United Methodist Church Addition; THENCE South 00 degrees 22 minutes 04 seconds East, along the West line of said Wylie United Methodist Church Addition, a distance of 1021.28 feet to a pk nail found for corner, said corner being the Southwest corner of said Wylie United Methodist Church Addition, and lying along the North line of McMillen Estates, an Addition to Collin County, Texas, according to the Map or Plat thereof recorded in Volume I, Page 719, Map or Plat Records of Collin County, Texas, and lying along the centerline of McMillen Road (public right-of-way); THENCE South 88 degrees 54 minutes 20 seconds West, along the centerline of said McMillen Road, a distance of 739.64 feet to a 1/2 inch iron rod found for corner, said corner being the Southeast corner of a tract of land conveyed to D-Dreams, Inc., a Texas Limited Liability Company, by deed recorded in County Clerk File No. 20070131000142850, Real Property Records of Collin County, Texas; THENCE North 00 degrees 03 minutes 00 seconds East, along the East line of said D-Dreams tract, a distance of 1100.59 feet to a 1/2 inch iron rod found for corner, said corner being the Southwest corner of a tract of land conveyed to Matthew M. Butschek and Catherine V.M. Butschek, husband and wife, by deed recorded in County Clerk File No. 97-001745, Real Property Records of Collin County, Texas; THENCE North 86 degrees 14 minutes 11 seconds East, along the South line of said Butschek tract (97- 001745), a distance of 208.03 feet to a 1/2 inch iron rod found for corner; THENCE North 00 degrees 31 minutes 31 seconds West, along the East line of said Butschek tract (97- 0001745), a distance of 172.53 feet to a point for corner; THENCE North 89 degrees 11 minutes 22 seconds East, along the South line of Butschek tract (97- 0001745), a distance of 1146.89 feet to a point for corner, said corner being the Southeast corner of that tract of land conveyed to Matthew M. Butschek and Catherine V. M. Butschek, husband and wife by deed recorded in County Clerk File No. 97-0001744 and lying along the West line of said City of Wylie tract and said FM Road 1378; THENCE South 00 degrees 08 minutes 09 seconds West, along the West line of said City of Wylie tract / FM Road 1378, a distance of 262.35 feet to the POINT OF BEGINNING and containing 1,067,190 square feet or 24.50 acres of land. 1 1 1 DRAFT 022420 Exhibit B MEADOW PONDS PLANNED DEVELOPMENT STANDARDS (Zoning Case 2020-02) A. Purpose The purpose of this planned. development district is to allow an age restricted mixed -use development on an approximate 24.5 acre parcel located on Tract 27 of the Williams Patterson Survey, West of FM 1378 and North of McMillen Road. This community will contain retail, personal service, health club, outdoor recreation, multifamily, assisted living, and single family uses. The regulations in this Planned Development (PD) District will encourage high -quality site planning and design in accordance with the City of Wylie's Comprehensive Plan. B. District Regulations 1. General. a. Subdistricts established: This PD shall be developed in three subdistricts as follows: i. Subdistrict 1: Single Family Subdistrict ii. Subdistrict 2: Multiplex Subdistrict iii. Subdistrict 3: Multiple -Care Subdistrict iv. The zoning exhibit (Exhibit C) shall serve as a subdivision concept plan for purposes of Zoning and Land Design, Street, and Sidewalk requirements. Separate plat submittals for all subdistricts shall be required. A separate site plan submittal for Subdistrict 3 shall be required. 2. Development of the Property shall generally conform to the following regulations: a. Single Family Subdistrict i. Except as otherwise provided herein, development of the Single Family Subdistrict shall comply with the Single Family-10 District regulations of the 2019 City of Wylie Zoning Ordinance. ii. Permitted Uses: Uses permitted in the Single Family-10 are permitted in the Single Family Subdistrict. Residential uses are restricted to a head of household aged 55 and older. iii. Development Standards: Following are the yard, lot and space requirements for the Single Family Subdistrict, including density, height, lot and unit size. Single Family Subdistrict Lot Size Minimum Lot Area (sq. ft.) 4,000 Minimum Lot Width (feet) 40 Minimum Lot Width of corner Lots- excepting the corner clip at the intersection (feet) 50 Minimum Lot Depth (feet) 100 Lot Depth of Double Front Lots (feet) NA Dwelling Regulations 24881861v.7 DRAFT 022420 Minimum Square Footage 1,100 Design Standards Level of Achievement See Section B.2.d below Yard Requirements — Main Structures Minimum Front Yard (feet) except between house facade and front street easement line 10 Minimum Front Yard (feet) between garage facade and front street easement line 20 Minimum Side Yard (feet) 5 Minimum Side Yard of Corner Lots (feet) 5 Minimum Side Yard of allowable nonresidential use (feet) NA Minimum Rear Yard (feet) 5 Minimum Rear Yard Double Front Lots (feet) NA Maximum Lot Coverage 80% Height of Structures Main Structure (feet) 30 Accessory Structure (feet) 14 b. Multiplex Subdistrict i. Except as otherwise provided herein, development of the Multiplex Subdistrict shall comply with the Multifamily District regulations of the 2019 City of Wylie Zoning Ordinance. ii. Permitted Uses: a. Except as otherwise provided herein, uses permitted in the Multifamily District are permitted in the Multiplex Subdistrict. b. Residential uses are restricted to a head of household aged 55 and older. iii. Development Standards: The following are the yard, lot and space requirements for triplex uses in the Multiplex Subdistrict, including density, height, lot and unit size. Multiplex Subdistrict Lot Size Minimum Lot Area (sq. ft.) 5 acres Minimum Lot Width (feet) 190 Minimum Lot width of corner Lots (feet) NA Minimum Lot Depth (feet) 135 Minimum Lot Depth of Double Front Lots (feet) NA Dwelling. Regulations Minimum Square Footage Studio- 470 sf 1 BR- 675 sf 2 BR- 875 sf Maximum Density 45Total units 24881861v.7 1 1 1 DRAFT 022420 Building Separation between detached buildings (feet) 10 Design Standards Level of Achievement See Section B.2.d below Yard Requirements — Main Structures Minimum Front Yard (feet) except between house facade and front street easement line 10 Minimum Front Yard (feet) between garage fagade and front street easement line 20 Minimum Side Yard of Corner Lots (feet) 5 Minimum Side Yard (feet) none Minimum Rear Yard (feet) 5 from any interior lot line Minimum Rear Yard Double Front Lots (feet) none Height of Structures Main Structure (feet) 30 Accessory Structure (feet) 14 c. Multiple -Care Subdistrict i. Except as otherwise provided herein, development of the Multiple -Care Subdistrict shall comply with the Multifamily District regulations. ii. Permitted Uses: a. Except as otherwise provided herein, uses permitted in the Multifamily District are permitted in the Multiple -Care Subdistrict. b. The following uses are permitted primary uses in the Multiple -Care Subdistrict: • Residential uses restricted to head of household aged 55 and older • Assisted Living Apartment • Nursing, Convalescent Home or Hospice (including memory care) c. The following uses are permitted accessory uses in the Multiple -Care Subdistrict: • Civic Center • Cultural Arts Facility • Financial Institution(without drive-thru) • Medical Clinic • Commercial Amusement or Recreation (Low -Density Inside) • Health Club • Theater • Cleaners • General Merchandise Store • Grocery Store • Personal Service Use • Restaurant without Drive-in or Drive -through Service • Post Office 24881861v.7 DRAFT 022420 iii. Development Standards: The following are the yard, lot and space requirements for triplex uses in the Multiple -Care Subdistrict, including density, height, lot and unit size. Multiple -Care Family Subdistrict Lot Size Minimum Lot Area (sq. ft.) 43,560 Minimum Lot Width (feet) 110 Minimum Lot width of corner Lots (feet) NA Minimum Lot Depth (feet) 90 Minimum Lot Depth of Double Front Lots (feet) NA Dwelling Regulations Building Separation between detached buildings (feet) 10 Minimum Dwelling Unit Square Footage Studio 470 sf 1 BR- 600 sf 2 BR- 875 sf Maximum Density 160 Total units Yard Requirements Minimum Front Yard (feet) 10 Minimum Side Yard of Corner Lots (feet) 5 Minimum Side Yard (feet) none Minimum Rear Yard (feet) 15 from any interior lot line Minimum Rear Yard Double Front Lots (feet) none Height of Structures Main Structure (feet) 60 Accessory Structure (feet) 14 d. Architectural Requirements. Development of the Property shall comply with the Architectural Requirements in the following table which replace the Architectural Requirements in Section the Zoning Ordinance: Architectural Requirements (For the Multiple -Care Subdistrict) ELEMENT BASE STANDARD (ALL DEVELOPMENT MUST COMPLY FULLY WITH ALL LISTED BELOW) Building Bulk and Articulation Minimum 25% of street facade offset minimum 2 ft, minimum 60% total area on 1st floor of all 2-story House Numbers • Stone plaque with number beside main entry 4 24881861v.7 1 1 1 1 DRAFT 022420 • Lighted wall front plaque Repetition of floor plan and elevation NA Exterior Facade Materials • Masonry, synthetic stone masonry, or fiber cement lap siding and panels • Masonry or fiber cement fascia, soffits and under hangs includes porches • Vinyl windows • Aluminum storefront for common amenity space • 30-year architectural shingles • Faux wood front door with and without glass inserts • Other materials permitted by the Zoning Ordinance Architectural Requirements (For the Single Family Subdistrict) ELEMENT BASE STANDARD (ALL DEVELOPMENT MUST COMPLY FULLY WITH ALL LISTED BELOW) Building Bulk and Articulation At least 20 percent of the facade shall be offset a minimum of 1-foot either protruding from or recessed back from the remainder of the facade. House Numbers • Stone plaque with number beside main entry • Lighted wall front plaque Exterior Facade Materials • Masonry or fiber cement lap siding and panels • Masonry or fiber cement fascia, soffits and under hangs includes porches • Faux wood front door with and without glass inserts • Operable and fixed vinyl windows • Faux cedar metal garage doors • 30-year architectural shingles • Other materials permitted by the Zoning Ordinance Exterior Facades- Porches Porches are not required Exterior Facades- Chimneys Chimney flues for fireplace chimneys are to be within a chimney enclosed with masonry matching exterior walls of the residential unit and capped. Roofs and Roof Pitching All single-family residential units shall have architectural -grade overlap shingles, tile, or standing seam metal. Wood shingles are not permitted. Plumbing vents, attic vents, and other rooftop accessories are to be painted to match the roof shingle color. 24881861v.7 DRAFT 022420 Minimum roof pitch shall be 4:12. Repetition of floor plan and elevation To avoid repetitious feel, a minimum of five (5) platted residential lots must be skipped on the same side and three (3) lots must be skipped on the opposite side of a street before rebuilding the same single-family residential unit with an identical (or nearly identical) street elevation design. The same floor plan shall not be repeated on neighboring, side by side lots or directly across the street. Identical or nearly identical floor plan means that the layout, size and function of the rooms are essentially the same. Identical or nearly identical street elevation design means little or no variation in the articulation of the facade, height or width of facade, placement of the primary entrances, porches, number and placement of windows, and other major architectural features. It does not mean similar colors, materials, or small details. Garage Entry To maximize the useable rear yards, garage doors can be located on the primary street elevation of a single-family residential unit. The primary street would be the addressed street front. Garages may face the street on a corner lot side yard. To provide ample parking and storage, each garage shall be a minimum of 400 square feet. Fencing No front yard fences are allowed. Side and rear yard fences shall be permitted to a height of 8 feet maximum and constructed of wood or wrought iron. Landscaping Each residential dwelling unit shall have sodded front, side, and rear yard with a minimum of 1 ornamental tree and 5 shrubs in front yard. All landscaped areas must be kept in a healthy and growing condition. Any plant materials that dies during a time of year where it is not feasible to replant shall be replaced as soon as possible. Each residential dwelling unit shall have an automated, subsurface irrigation system. Architectural Requirements (For the Multiplex Subdistrict) ELEMENT BASE STANDARD (ALL DEVELOPMENT MUST COMPLY FULLY WITH ALL LISTED BELOW) Building Bulk and Articulation At least 20 percent of the facade shall be offset a minimum of 1-foot either protruding from or recessed back from the remainder of the facade. House Numbers • Stone plaque with number beside main entry 6 24881861v.7 1 1 1 1 1 DRAFT 022420 • Lighted wall front plaque Exterior Facade Materials • Masonry or fiber cement lap siding and panels • Masonry or fiber cement fascia, soffits and under hangs includes porches • Faux wood front door with and without glass inserts • Operable and fixed vinyl windows • Faux cedar metal garage doors • 30-year architectural shingles • Other materials permitted by the Zoning Ordinance Exterior Facades- Porches Porches are not required Exterior Facades- Chimneys Chimney flues for fireplace chimneys are to be within a chimney enclosed with masonry matching exterior walls of the residential unit and capped. Roofs and Roof Pitching All single-family residential units shall have architectural -grade overlap shingles, tile, or standing seam metal. Wood shingles are not permitted. Plumbing vents, attic vents, and other rooftop accessories are to be painted to match the roof shingle color. No minimum roof pitch is required. Repetition of floor plan and elevation Repetition of floor plan and elevations is not required for the Multiplex Subdistrict. Garage Entry To maximize the useable rear yards, garage doors can be located on the primary street elevation of a single-family residential unit. The primary street would be the addressed street front. Garages may face the street on a corner lot side yard. To provide ample parking and storage, each garage shall be a minimum of 200 square feet. Fencing No front yard fences are allowed. Side and rear yard fences shall be permitted to a height of 8 feet maximum and constructed of wood or wrought iron. Landscaping Each residential dwelling building shall have sodded front, side, and rear yard with a minimum of 1 ornamental tree and 3 shrubs in front yard. All landscaped areas must be kept in a healthy and growing condition. Any plant materials that dies during a time of year where it is not feasible to replant shall be replaced as soon as possible. 24881861v.7 DRAFT 022420 Each residential dwelling unit shall have an automated, subsurface irrigation system. e. Land Design Requirements. Development of the Property shall comply with the Land Design Requirements in the following table which replace the Land Design Requirements in the Zoning Ordinance: Land Design Requirements (For all Residential Districts) ELEMENT a. BASE STANDARD (ALL DEVELOPMENT MUST COMPLY FULLY WITH ALL LISTED BELOW) Public Open Space Easements 30 ft wide buffer with 8 ft wide trail throughout Property Trail amenities to be provided such as benches, fitness station, or picnic tables Perimeter Screen Along Thoroughfares 40 ft wide buffer, w/6 ft wrought iron between brick or stone columns (50 ft o.c.) or landscaped earthen berm (3:1 slope) Increase buffer width by 10%, slip street/parkway with no residential lots backing or siding on thoroughfare Perimeter Walkways and Landscape a. Mixture of large/canopy and small/omamental trees 50 ft. o.c. b. 8 ft walk/trail. c. Provide benches at nodes when adjacent to open sp ace. Lighting and Furnishings along open space easements and trails Solar -controlled lighting on 10-12 ft decorative poles every 100 ft, common throughout. Benches with backs every 1/2 mile or portion thereof when adjacent to open space. Decorative paving and cross -walks at street connectors. Exercise apparatus every % mile a. Trees 30 ft o.c. maximum, with down lighting and ground -level lights. 24881861v.7 8 1 1 1 1 DRAFT 022420 f. Street and Sidewalk Requirements. Development of the Property shall comply with the Street and Sidewalk Requirements in the following table which replace the Street and Sidewalk Requirements in the Zoning Ordinance: Street and Sidewalk Requirements (For all Residential Districts) ELEMENT BASE STANDARD DEVELOPMENT MUST COMPLY BELOW) Curvilinear Streets NA Entry Features and Medians Architectural features on stone screen wall or stone monument (no brick) Tubular steeel accent panels, or water feature, or 2 or more different type/color of stone (can be synthetic or cultured). Signage at Entries Incorporated into screen wall or monument sign within median and illuminated by means other than street lights. Street Name Signs Including block numbers, incorporated with street lighting coordinated throughout. Unique neighborhood design, or back- lighted. Pedestrian Crosswalks 10 ft or wider, connected system of decorative pavers. Sidewalk Locations 5 ft concrete, both sides of street, meandering continuous pathway. Mail Boxes Paired at lot line on SF-10 Lots or lower. Number plaque, brick same as resident. Stone, same house exterior trim. Sidewalk Lighting Low -illumination with solar controls, on decorative poles every 250' to 350' apart (intersections & mid -block alternating sides). Perimeter Alleys NA g. General Provisions i. The Multifamily residential proximity slope (Section 7.1) does not apply to development within the Property as it would pertain to other development within the property. 24881861v.7 DRAFT 022420 ii. On -street parking shall be prohibited and so marked with signage. iii. Properties may be addressed using the private drives on which they front. iv. Parking for the Multiple -care facility shall be provided at a minimum of 165 spaces to serve a maximum of 160 residential units and the allowed commercial uses within the sub -district. v. A minimum of: (i) building permit shall be issued by the City of Wylie Building Official for the primary structure within the Multiple Care District (as diagrammed on the Zoning Exhibit); and (ii) an approved final foundation inspection shall be completed by a City of Wylie building inspector on the primary structure of the Multi Care District before a Final Inspection or Certificate of Occupancy will be allowed for any residential unit in Sub -districts 1 or 2, Single family and Multiplex, respectively; and (iii) an approved final framing inspection shall be completed by a City of Wylie building inspector on the primary structure of the Multi Care District before a Final Inspection or Certificate of Occupancy will be allowed for any residential unit over 50% of planned units in Sub -districts 1 or 2, Single family and Multiplex, respectively; and (iv) an approved Temporary Certificate of Occupancy by the City of Wylie Building Official on the primary structure of the Multi Care District before a Final Inspection or Certificate of Occupancy will be allowed for any residential unit over 95% of planned units Sub -districts 1 or 2, Single family and Multiplex, respectively. vi. A completed Traffic Impact Analysis, as outlined by The City of Wylie Subdivision Regulations (9/19) Section 3.13.3, shall be submitted with the preliminary plat; and be reviewed by City of Wylie Engineering before the preliminary plat can be approved for construction. vii. The planned development zoning exhibit shall be included as a development condition. If, in the opinion of the City Planner, a site plan (Sub -district 2 & 3) or plat (Sub -district 1, 2, or 3) does not generally conform to the zoning exhibit approved by the City, the applicant shall either seek approval of a revised zoning exhibit through re -zoning or submit a revised site plan. 24881861v.7 10 1 1 MEADOW PONDS CITY OF WYLIE COLLIN COUNTY, TEYAS ZONING EXHIBIT NO ..FM13713 CdUNTRYC[UBROAD Kimley»»Horn CS media The Farmeasville Times • Murphy Monitor • The Princeton Herald • 74-Sachs News • THE WYLIE NEWS STATE OF TEXAS COUNTY OF COLLIN Before me, the undersigned authority, on this day personally appeared Chad Engbrock, publisher of C & S Media, dba The Wylie News, a newspaper regularly published in Collin County, Texas and having general circulation in Collin County, Texas, and being in compliance with Section 2051.044, Texas Government Code (a); (1), (2), (3) and (4), who being by me duly sworn, deposed and says that the foregoing attached: City of Wylie Legal Notice —Ordinance No. 2020-30 and Ordinance No. 2020-35 was published in said newspaper on the following date(s), to -wit: June 3, 2020 Chad Engbrock, Publisher Subscribed and sworn before me on this, the 4th day of June, 2020 to certify which witness my hand and seal of office. Al(14//1, SONIA A. DUGGAN ?= P'' "'e%Notary Public, State of Texas s• e Comm. Expires 08-18-2020 ''i oF�`` Notary ID 130783749 Notary Public ir►F or The State of Te My commission expires 08/18/2020 N1urplay SacheOffice • 1 10 N. tialItuil • P.O. liox 369 • Ydt lic 'I `t, 75091 • 972-442-:'515 • tax 972--142-4318 Farmertivillc/Princeton Office • 101 5. T,vttun • P.O. 13ux 512 • FarmersFillc,'l \ 75442 • 97' 784-05 )7 • lax 972 752-702.3 CITY OF WYLIE Ordinance No. 2020-30 An ordinance of the city of Wylie, Texas, amending the com- prehensive zoning ordinance of the City of Wylie, as hereto- fore amended, so as to change the zoning on the hereinafter de- scribed property, zon- ing case number 2020- 02 from I agricultural (ag) to planned devel- opment (pd), to allow for a mixed use age re- stricted master planned community; providing, for a penalty for the violation of this ordi- nance; providing for the repeal of all ordi- nances in conflict;' pro- viding a severability clause; and providing for an effective date. Ordinance No. 2020-35 An ordinance of the city council of the City of Wylie, Texas, amending ordinance nos. 2020-24, 2020- 25, -2020-26, 2020-29, and 2020-31 and con- tinuing and, extending the Mayor's amended declaration of Iocal di- saster for public health emergency due to the novel coronavirus (covid-19); providing the consent of the city council to the continu- ation of the declara- tion until 11:59 p.m. on June 9 2020; pre- scribing orders to help abatethe public health emergency; providing authority for the city council to terminate the disaster declara- tion; and providing an enforcement clause, severability clause and an El-FEC'IIVE DATE. L5-1t-711