Ordinance 1985-56
ORDINANCE NO.
~-66
AN ORDINANCE AMENDING ORDINANCE NO. 83-18 SUBDIVISION
REGULATIONS OF THE CITY OF WYLIE, TEXAS; REDUCING THE P.S.I.
FOR REINFORCED CONCRETE PAVEMENT AS SET FORTH IN SECTION
6.02, PARAGRAPH B. SUBSECTION 1 PARAGRAPH 3, SUBSECTION 2
PARAGRAPH 7 AND SUBSECTION 3 PARAGRAPH 6; AMENDING SECTION
6.06 PARAGRAPH B; PROVIDING FOR AN EFFECTIVE DATE AND
PROVIDING FOR SEVERABILITY.
WHEREAS, the City Council of the City of Wylie deems it
proper and necessary to change the following sections of the
Subdivision Regulations of the City of Wylie;
THEREFORE, the following sections shall read:
6.02
STREET PAVING - CONCRETE
B. PAVEMENT REQUIREMENTS
1 .
Non-collector Residential
Alley Construction
Street and
Paragraph 3. A six (6) inch thickness
of three thousand five hundred (3500)
p.s.i. reinforced concrete pavement on a
compacted subbase shall be required.
2. Residential Collector Streets and/or
Streets and Alleys within Commercial-
Industrial Zones
Paragraph
alleys,
shall be
eight (8)
hundred
concrete
subbase.
7. Collector streets and
as defined by this section,
designed and constructed with
inch of three thousand five
(3500) p.s.i. reinforced
pavement on a compacted
3. Maior Thoroughfare and Commercial-
Industrial Collector Streets
Paragraph 5. Thoroughfares shall be
designed and constructed with an eight
(8)inch thickness of three thousand five
hundred (3500) p.s.i. reinforced
concrete pavement on a compacted
subbase.
6.06
WATER SYSTEM
B.
IN cul-de-sacs
(300) feet in
not required
used.
of less than three hundred
length where a fire hydrant is
six inch (6") mains may be
RESCIND: AMENDMENT OF AUGUST 13,
p.s.i and No.4 reinforcing bars
steel forms.
1985 calling for 4000
and the requirement for
EFFECTIVE DATE: This ordinance will become effective
immediately upon passage by the City Council of the City of
Wylie and upon publication of the caption in the Wylie News.
APPROVED ON
, 1985.
THIS THE
#~
DAY
OF